Request a Bulk Quote

Tell us the unit count and the timeframe. We come back with written pricing, the Intertek certificate and the specification, in a form you can put in front of a board or a procurement team.

We reply to bulk quote requests within one business day, Monday to Friday.

Bulk Orders And Quotes

New York City Class A and Class B multiple dwellings need compliant natural gas alarms installed by January 1, 2027. One or more alarms may be required in each dwelling unit, because every fuel-gas-burning appliance has to be covered by an alarm in the same room and within the required placement distance. If you are responsible for a portfolio rather than a home, that is a procurement and logistics problem with a fixed end date. ChesGuard supplies the CG-GD1 in volume with pricing, documentation and rollout support built around that deadline. Tell us the unit count and the timeframe and we will come back with a quote.

Who This Page Is For

  • Property managers and managing agents running multi building portfolios
  • Building owners and landlords with Class A or Class B multiple dwellings
  • Co-op and condo boards planning a building wide rollout
  • Superintendents and maintenance teams who will do the installation in house
  • Housing providers, developers and general contractors specifying for new occupancy. Note that battery-powered alarms may be used in qualifying existing buildings, and different power requirements may apply to buildings completed on or after January 1, 2027, so confirm the power requirement before you specify.

Why A Battery Alarm Collapses Your Installation Cost

Under 1 RCNY 908-02(g), a line powered natural gas alarm has to be installed by a New York City licensed electrical contractor and requires permits. In qualifying existing buildings, a battery powered alarm may be installed by the owner, by maintenance personnel or by the occupant. No electrician, no permit, no electrical work. Different power requirements may apply to buildings completed on or after January 1, 2027.

On a portfolio of any size this is where the money is. A hardwired rollout means a licensed contractor, permit filings, a coordinated unit access schedule that has to fit somebody else's calendar, and a per unit labor cost that frequently runs higher than the device itself. A battery rollout means a cordless drill, the supplied mounting hardware, and your own superintendent working through a floor at a time. The compliance outcome under the rule is identical. The difference is measured in months of scheduling and in labor you do not have to buy.

What We Supply

  • Volume pricing scaled to the unit count, quoted per order rather than published, because a 40 unit building and a 4,000 unit portfolio are not the same job
  • Delivery scheduling agreed with you at the time of quoting, so stock arrives in line with your installation plan
  • Compliance documentation including the Intertek Certificate of Compliance and the manufacturer's stated useful life, which owners are required to record
  • Installation material for your maintenance team, including the placement rules and the test procedure in a form you can hand to staff
  • Bilingual manuals in English and Spanish, in the box on every unit
  • Replacement cycle planning based on a battery designed to last approximately 10 years from activation and an alarm service life of approximately 10 years from installation, so the next cycle is scheduled rather than discovered

The Product You Are Quoting

Specification CG-GD1
Detected gas Methane (natural gas)
Sensor sensitivity 10% LEL
Power DC3V built-in lithium battery, no wiring and no battery replacement
Battery design life Approximately 10 years from the date of activation
Alarm service life Approximately 10 years after the installation date, then replace the unit
Alarm output 85 dB at 10 feet
Listing ETL Listed by Intertek, conforms to UL Standard 1484:6ED 2025-02-28
Intertek control number 5017086
Installation Wall mounted with the supplied mounting hardware. No electrician and no permit for qualifying battery-powered installations.

The full detail sits on the spec sheet, and the compliance background is on the Local Law 157 guide.

How Many Alarms Will You Need?

Count appliances and rooms rather than units. A studio with a range and a gas water heater in the same room is usually one alarm. A two bedroom apartment with a range in the kitchen and a gas dryer in a separate laundry room is two, because no single position covers both rooms within the required 3 to 10 feet. If you are not sure, send us a typical floor plan with the quote request and we will work it through with you.

Request A Quote

Use the form at the bottom of this page. It takes about a minute, and we reply within one business day, Monday to Friday. If you would rather email, send the same detail to support@chesguard.com.

  • Company or organization name
  • Contact person
  • Email address
  • Phone number
  • Property address or project location
  • Number of buildings
  • Number of apartments or units
  • Estimated quantity of alarms, 1 to 49, 50 to 499, or 500 or more
  • Desired installation or delivery timeframe
  • Any additional project information

Send as much of that as you have. A unit count and a target date are enough to start a conversation, and we can work the rest out from there.

What Happens Next

  1. We confirm the quantity, the delivery points and the timeframe.
  2. We send written pricing with the certificate and the specification attached, in a form you can put in front of a board or a procurement team.
  3. You confirm, and we agree a delivery schedule that fits your installation plan.
  4. Your team installs, using the supplied mounting hardware. No electrician and no permit for qualifying battery-powered installations.

Questions before you send anything, or an unusual building type you are not sure about? Email support@chesguard.com and ask.